Steelman Industries, Inc
P.O. Box 1461
2800 Hwy. 135 North
Kilgore, TX 75662

Phone: 903-984-3061
Fax: 903-984-1384

Rotary Phase Converters

Submersible Pumps

Submersible pumps are designed to run overloaded; therefore, they require more power than a typical motor at the same horsepower rating. Because of this, Steelman recommends choosing a heavy-duty phase convertor and only running one submersible pump per phase convertor for pumps over 10hp. For more information contact Steelman Industries.

Center Pivot Irrigation Equipment

Irrigation applications are great candidates for powering with a phase convertor. In the case of a center pivot system, sizing the convertor requires some special considerations. The following table gives Phase Convertor sizes for pivot systems with no booster pumps or end guns.

Sizing Table for Center Pivot Systems With No Auxiliary Motors

HP rating of
Tower Motors
# of Towers Phase Convertor Required
.75 3-4 R3/10-460-HD
- 5-6 R5/15-460-HD
- 7-10 R7.5/20-460-HD
1 3 R3/10-460-HD
- 4-5 R5/15-460-HD
- 6-7 R7.5/20-460-HD
- 8-10 R10/30-460-HD

For pivot systems with booster pumps and end guns, simply add up the hp of all towers, end guns, and booster pumps. This gives you the total running hp, which is the second number in the rotary model #. To determine the starting rating of the convertor (the first number in the rotary model #), use 60% of the total hp of the tower motors or the hp rating of the largest pump, whichever is greater. If the pivot will ever run dry or will run without the booster pump running, then you must add the terminal block option (/TB1 or /TB2). This allows the phase convertor to run in a light-loaded condition without causing an over voltage situation. Please contact the factory for further assitance.

Computer Controlled Equipment/CNC

To achieve the voltage balance and stability required by CNC equipment, Steelman offers the CNC line of phase convertors.

CNC Motor Size Steelman Rotary Convertor
(xxx Denotes Voltage: 208, 230, or 460)
Rotary Motor Size
2 R3-xxx-CNC 10
3 R5-xxx-CNC 10
5 R7.5-xxx-CNC 20
7.5 R10-xxx-CNC 20
10 R15-xxx-CNC 30
15 R20-xxx-CNC 30
20 R25-xxx-CNC 40
25 R30-xxx-CNC 50
30 R40-xxx-CNC 60

Elevators/Float Switch Applications/Unattended Applications

For applications that run intermittently and are unattended, special consideration needs to be taken so that the phase convertor does not run continuously unloaded. Steelman offers an automatic (/A) option for these applications. This option consists of a switch and timer system that will start the phase convertor first, allowing it to get up to speed, and then start the load motor. After the load motor shuts off, the phase convertor will run a predetermined amount of time to allow for quick restart of the load motor, and then shut off.